Calculating shortcircuit current on secondary of main transformer. Is a the current at the secondary coil ip a the current at the primary coil note that the electrical power in the primary coil and secondary coil are the same. An infinite bus shortcircuit calculation can be used to determine the maximum shortcircuit current on the secondary side of a transformer using only transformer nameplate data. Customers should be advised that the fault current calculations were performed using infinite bus at the transformer secondary terminals. Lets say we have a transformer rated 1500 kva with a secondary voltage of 480y. The image shows a simple electrical system around a transformer primary voltage v p, secondary v s. Simple methods for calculating short circuit current without a. I have a question on how to calculate auto transformer secondary fault currents. A 3 phase transformer has three magnetic circuits that are interlaced to give a uniform distribution of the. Calculate the winding impedances for cases 3 and 5 listed in table 1, and then. Transformer current calculator voltage disturbance.
The term inrush current means the current at the time of energising the transformer every time to a healthy down stream circuit. Three phase transformers divide the values for vs secondary voltage by v3 and the va. Short circuit currents impose the most serious general hazard to power distribution. Single phase transformer fullload current amps kva. Calculator this calculation is based on the infinite source method at the primary of the transformer, the following calculates the fault current at the transformer secondary terminals. Per unit analysis can be used to calculate system three phase fault levels and the current distributions. Because, the voltage level on the primary of the transformer is different than the secondary, the two values of current will be different.
Fault current calculations are based on ohms law in which the current i. How do you calculate the maximum possible available fault. Calculate fault current at each stage of following electrical system sld having details of. The inherent secondary fault current for a 204050mva, 115kv, 8%impedance transformer would be. This calculator helps determine the current values on both sides of the transformer, and estimates available short circuit current. Insert the the kva rating power factor pf and impedance z of the transformer is not required to continue. Infinite bus short circuit calculation brainfiller, inc. Transformer calculator kva calculator full load amps. If for some reason you need a larger transformer to operate appliances, you still divide the wattage by the voltage to find the current. Welcome to schneider electrics fault current calculator. To increasedecrease the alternating volts in electric power, transformers are used. Before the available fault current for equipment within your facility can be determined, you need to know the available fault current at the secondary terminals on the utility transformer feeding your facility.
How to calculate fault current for transformer answers. This can also be used as a transformer kva calculator and transformer secondary short circuit current calculator. The ln fault current is higher than the ll fault current at the secondary terminals of a singlephase centertapped transformer. The peak let through with an infinite source worst case scenario would have 208 0. If you put a dead short on the secondary and slowly increase the primary voltage from zero until the secondary current is at the rated maximum. The fault current of a power transformer will depend on the following. There can be a variation in the transformer impedance values, but generally the transformers that blakley electrics use will be in the 45% range of primary voltage. Transformer capacity calculator three phase transformer. Step 2 calculate the short circuit current on the transformer secondary bus. Transformer fault current calculation electrical engineering portal. Threephase shortcircuit current isc calculation at any. As i understand it an auto transformer will transform only a portion of the required secondary current and the rest is supplied directly from the primary line. Transformer rating in kvamva per unit impedence of the transformer %p.
For a zero impedence three phase fault on the secondary side of 100 kva and before 150 kva, the fault kva will be 100. Once the fault currents have been calculated, you can then select overcurrent. Short circuit analytic sca software and mobile apps perform available short circuit fault current calculations in threephase electric power systems you are working with. Short circuit calculations with transformer and source. Step 3 calculate the short circuit current on the transformer secondary bus, but this time we use the transformer impedance and the source impedance. Shortcircuit calculations using transformer and source. Enter the primary and secondary transformer voltages. Those would include such software applications as skm systems analysis tools.
One criterion in selecting a distribution substation transformer protective device is its ability to protect the transformer from secondaryside limited faults or. Click on the calculate button to obtain the results. Lets first consider base kva and kv for ht and lt side. Overstressed device alarms are displayed on the oneline diagram and included in short circuit analyzer and study reports. To calculate the maximum fault current that can be achieved in a circuit fed by a transformer we refer to the below formula this formula calculates the loop impedance at the end ofa circuit fed from the secondary winding of a transformer. Electrical calculator mc group electrical calculation. This is how they determine the impedance of power transformers without destroying them. For a 120volt primary, 2000watt transformer, divide 2000 by 120 for the current 2000 watts 120 volts 16. Transformer fault current calculation blakley electrics. This quick calculation can assist you identify the fault current on the secondary of a transformer for the aim of selecting the proper overcurrent protective devices which can interrupt the available fault current. How do you calculate the maximum possible available fault current. A protective device is appropriate for the application if its secondary fault interrupting rating is equal to or greater than the value for i calculated above.
Where one transformer is larger than the others in the bank, use the fault current value for the larger transformer. Or if you have the available fault current, either given to you from utility, or if you are using this program to calculate fault currents at other parts of the system where the aic ampere interrupting capacity is known, input this number and it will automatically override the. The transformer calculator uses the following formulas. It is interesting to see that increasing the available fault current from the utility, assuming a starting point of 50 ka, doesnt have as great of an impact as one would think. Calculator can be used for step down transformer as well as step up transformer sizing applications. Enter the transformer rating and select the appropriate unit. Insert available fault current ampere rating from your local utility step 1b. Fault current full load amps % impedance z example. Secondary fault current tables effective october 24, 20 page 4 of 27 this information is only for use in determining service equipment ratings and is not to be used for selecting personal protective equipment. Easy and simple methods for calculating short circuit curr.
This design solves the fault current problem however the transformation costs. Calculates the short circuit fault current level of a transformer on an infinite bus. Fault current calculations are a critical piece of the electrical designengineering puzzle for electrical distribution systems in commercial and industrial installations. In a real transformer, due to losses, the power at the secondary coil will always be smaller than the power at the primary coil. It has two types, single phase and three phase transformer. Short circuit current calculations cooper industries. In this situation, we assume cable length to be minimal and therefore neglect its. How to calculate transformer primary current sciencing.
A fault, i fs shown on the secondary, will also been seen on the primary side of the transformer i fp. This is usually provided by the utility and gives the maximum possible fault current. Distribution transformer calculator free download and. Short circuit current at transformer calculation 08282010 9. For example, doubling the utility available fault current from 50 ka to 100 ka only increases the transformer secondary available fault current by 3%, or 1,022 amps. Selecting overload protection and wires for transformers involves number of rules that change with transformer size, type, and placement of the overload protection. Calculate the maximum fault current for a transformer rated. An online three phase transformer calculator to find the current in different power units. This is a good and simple method for determining the worstcase maximum shortcircuit current through the transformer since it ignores the sourceutility impedance. If you need assistance with circuit protection devices such as fuses or breakers, or wire sizing, please consult a licensed electrical contractor or electrician in your area who will be familiar with state and local codes. Transformer maximum fault current allowing for loog impedance. Current of protective circuit breaker short circuit fault current short circuit faultvoltage losses of the distribution transformer.
Perform device duty calculations using etaps short circuit analysis software which allows you to determine fault currents and automatically compare these values against manufacturer short circuit current ratings. For calculation of the maximum fault current that can be potentially achieved within a transformer fed circuit, we use the formula shown in the tool screenshots beginning with. Shortcircuit current calculations cooper industries. The short circuit current is given by 1to calculate the short circuit current at lv bb 1,the total. Distribution transformer fault current tables for transformers in the downtown network area contact a network design representative to obtain the fault current. Transfomer rating kva secondary transformer voltage v transfomer. How to calculate the fault current at the primary side of. Three phase fault example three phase fault example. Input the nameplate transformer impedance as a percentage, not a decimal i. Transformer short circuit fault current calculator jcalc. Use the 3 phase and single phase transformer sizing calculator below to calculate primary and secondary full load current. Calculate the shortcircuit current at the secondary of the transformer. Distribution transformer impedance and fault currents. This quick calculation can help you determine the fault current on the secondary of a transformer for the purpose of selecting the correct overcurrent protective devices that can interrupt the available fault current.
Replacements that result in a higher possible fault current, than that of the existing equipment, shall be addressed to this department, prior to reconnection of existing service equipment. See note under step 3 of basic pointtopoint calculation procedure. For example, a 75kva transformer with a 208y120 secondary and 5% impedance has a capacity of 208 amps on the secondary. A fault current calculation determines the maximum available current that will be available at a given node, or location, in the system. The programs take into consideration all of the key electrical parameters of power distribution system including power supply, cables, transformers, motors and generators. Short circuit analysis short circuit software etap.